The complete system specification sets out the requirements for the Western Colloid SM-1P-10-A fluid applied reinforced roof system. It upgrades a smooth surface or cap sheet with one ply of polyester fabric and an aluminum reflective surface. The five-page PDF is revised 10/20.
Part 1 lists the applicable ASTM, U.L. and Western Colloid detail publications, the pre-roofing conference, and a two-year contractor warranty. The environmental conditions set a minimum application temperature of 55°F and rising. It states that Western Colloid is not responsible for overspray damage.
The system components table lists a base coat of #298 emulsion at 5 gallons and 19 lb, one ply of polyester fabric at 2.5 lb, a top coat of #298 emulsion at 5 gallons and 19 lb, and 1.5 gallons of SilverWhite aluminum at 4.5 lb. Dry weight is 45 lb per 100 square feet and thickness is about 90 mils. Part 2 describes the assembly as a cold process upgrade for existing BUR and modified bitumen roofing. Materials include W26/T326 or T272 polyester fabric, All Weather Elastic Cement #8000 and Elastic Cement #800.
Material changes / notes
Official manufacturer document matched through the system page document filters. Confirm its revision and applicability at source before use.