Revision context
Document record
Western Colloid’s SM-2P-16-A specification covers a fluid applied reinforced roof system for a smooth surface or cap sheet, with two plies of polyester fabric and an aluminum reflective surface. The five-page PDF is revised 10/20.
Part 1 lists the applicable ASTM, U.L. and Western Colloid detail publications, the pre-roofing conference, a two-year contractor warranty and the manufacturer certifications the contractor must hold. Part 1 also sets the application conditions, including a minimum temperature of 55°F and rising.
The system components table lists a base coat of #298 emulsion at 6 gallons and 23 lb, two plies of polyester fabric at 5 lb, an interply coat of #298 at 5 gallons and 19 lb, a top coat of #298 at 5 gallons and 19 lb, and 1.5 gallons of SilverWhite aluminum at 4.5 lb. Dry weight comes to 70.5 lb per 100 square feet, or about 140 mils. Part 2 describes the assembly as a cold process upgrade over BUR and modified bitumen, and lists W26/T326 or T272 fabric and All Weather Elastic Cement #8000 as materials.
Material changes / notes
Official manufacturer document matched through the system page document filters. Confirm its revision and applicability at source before use.