The complete system specification sets out the requirements for the Western Colloid SMEA-2P-14-3G-6xE fluid applied reinforced roof system. The specification covers recovering a smooth surface, cap sheet or single-ply membrane. The five-page PDF is revised 10/20.
The system is built from a membrane of one ply of polyester and glass fiber roving and a surface of one ply of polyester in acrylic. Part 1 covers the quality control requirements, with the two-year contractor warranty and the pre-roofing conference, plus the storage and handling rules for materials kept on the roof.
The system components table lists seven items: a base coat of #298 emulsion at 5 gallons and 19 lb, one ply of polyester fabric at 2.5 lb, a top coat of #298 emulsion at 9 gallons and 35 lb, 3 lb of chopped glass roving, a base coat of ElastaHyde at 3 gallons and 21 lb, one ply of polyester fabric within the ElastaHyde, and a surface coat of ElastaHyde white acrylic at 3 gallons and 21 lb. The dry weight totals 104.0 lb per 100 square feet, about 185 mils thick. Part 2 lists U.L. Class A, California Title 24, LEED and ENERGY STAR as the assembly criteria.
Material changes / notes
Official manufacturer document matched through the system page document filters. Confirm its revision and applicability at source before use.