Technical document revision

Tite-Loc Steel Spec (DOCX)

StatusCurrent
Last verifiedSeptember 7, 2026

Revision context

Document record

The file is a Word guide specification titled Tite-Loc Steel, dated August 2024. Section 07410 is titled Preformed Metal Standing Seam Roofing and applies to a pre-finished roof system from Petersen Aluminum Corporation. The scope covers factory formed standing seam panels, and the related work named is structural steel, steel joists and sheet metal flashing. Material is listed under two standards: ASTM A653 zinc-coated or zinc-iron alloy coated steel at 24 gauge, and ASTM A792 aluminum-zinc coated steel at 22 gauge, with the gauge chosen by the specifier.

Panels must meet water penetration limits under ASTM E283 and E331 and a UL Class 90 wind uplift rating under UL 580, with ASTM E1592 testing and UL 2218 impact resistance. The file gives a 20-year weathertight term from substantial completion, a 30-year finish term, and a two-year applicator term. Deterioration is defined by fading over 5 Hunter units, measured by ASTM D2244, and chalking over a No. 8 rating, measured by ASTM D4214. The file also includes an ordering section, submissions, delivery and storage, and project conditions.

Material changes / notes

Official file linked from the current catalogue. No local archive copy is retained. Publication date and revision have not been verified.

Applicability

Related products

Current Code: Tite-Loc

Tite-Loc

A mechanically seamed roof panel using a 90-degree field lock. Floating concealed clips allow movement while retaining the panel within the selected roofing assembly. Record scopeThis page is the product-level record for Tite-Loc. It separates this product from similar lines, variants and generations so that

Family: Standing-seam roofing

View permanent product record

Provenance

Archive and verification record

First discovered
September 7, 2026
Last verified
September 7, 2026

View the original manufacturer source

Report incorrect or outdated information