Product overview
The DM40-F+ meets ASTM E119 for 1-hour fire-rated walls. Its lightweight InnovaCELL™ core allows faster installs and easier handling. Strong and rigid, it supports longer lengths and vertical installation. Closed-cell foam helps block vapor and cut condensation.
Manufacturer-recorded characteristics
- Tested and certified to meet ASTM E119 standards for 1-hour fire-rated wall assemblies, ensuring code compliance and safety.
- High thermal performance combined with fire-resistant properties, ideal for projects requiring both insulation excellence and a 1-hour fire rating without compromise.
- Lightweight InnovaCELL foam core enhances ease of handling and increase installation speed versus traditional fire-rated assemblies
- Strength and rigidity of DM40-F+ enables longer panel lengths and design flexibility
- Closed-cell foam technology mitigates vapor intrusion and reduces condensation risk compared to mineral wool.
- Panel joinery is designed to permit installation of the panel vertically
- Reduces the number of materials and steps needed, cutting down on labor time and installation costs
Record scope
This page is the product-level record for DM40-F+ with InnovaCELL™ Technology. It separates this product from similar lines, variants and generations so that specifications and data sheets can be checked against the correct identity.
- Product family: Insulated metal panel system
- Recorded applications: Commercial, industrial and controlled-environment building envelope
- Market: United States
- Manufacturer: All Weather Insulated Panels
Key recorded details
These values summarize reviewed manufacturer information. Use the linked source for tolerances, options, exclusions and complete assembly requirements.
- Manufacturer feature 1: Tested and certified to meet ASTM E119 standards for 1-hour fire-rated wall assemblies, ensuring code compliance and safety.
- Manufacturer feature 2: High thermal performance combined with fire-resistant properties, ideal for projects requiring both insulation excellence and a 1-hour fire rating without compromise.
- Manufacturer feature 3: Lightweight InnovaCELL foam core enhances ease of handling and increase installation speed versus traditional fire-rated assemblies
- Manufacturer feature 4: Strength and rigidity of DM40-F+ enables longer panel lengths and design flexibility
- Manufacturer feature 5: Closed-cell foam technology mitigates vapor intrusion and reduces condensation risk compared to mineral wool.
- Manufacturer feature 6: Panel joinery is designed to permit installation of the panel vertically
- Manufacturer feature 7: Reduces the number of materials and steps needed, cutting down on labor time and installation costs
Matched current documents
The following current files are connected directly to this product record. Older revisions remain in the archive when moderators retire them.
- DM40-F+ with InnovaCELL Product Data Sheet
- DM40-F+ Interior Partition Load Span Table
- Dm40-F+ InnovaCELL Specification
Design and specification coordination
Use these checks to connect the product record to a complete, project-specific assembly. The manufacturer documents and approved construction documents govern where they provide more specific requirements.
- Confirm panel profile, coverage width, seam or rib geometry, metal type, gauge or thickness and finish.
- Coordinate minimum slope, substrate, underlayment, clip or fastener selection and allowance for thermal movement.
- Verify perimeter, ridge, valley, transition, penetration and closure details with the selected panel configuration.
- Check tested wind-uplift, fire, water and air assemblies against deck type, span and attachment spacing.
- Record manufacturing length limits, field-seaming requirements, finish availability and protection during storage and handling.
Submittal and field verification
A useful product record should allow a reviewer to trace what was specified, approved, delivered and installed. Include the following items when this product is proposed or verified.
- Use the exact product name and manufacturer identifier on the submittal; do not substitute a similar family name.
- Attach the current product data sheet and the applicable installation, safety, approval and warranty documents.
- Record selected options such as size, thickness, profile, color, finish, reinforcement and attachment method.
- Identify the tested or approved assembly and list each adjoining component needed to reproduce it.
- At delivery, compare labels and revision dates with the approved record and archive superseded files instead of overwriting them.
Selection, installation and existing-roof checks
Confirm the exact product name, generation and configuration before using any value on this page. Check the roof substrate, slope, attachment or adhesive, reinforcement, edge and penetration details, accessories, tested assembly and local approval that apply to the project. For an existing roof, compare labels, package records, original submittals and physical dimensions; appearance alone is not enough to identify a product.
Applications and product scope
Recorded applications
- Commercial, industrial and controlled-environment building envelope
Record scope
- Product family: Insulated metal panel system
- Recorded market: United States
- Product code: DM40-F+ with InnovaCELL™ Technology
Technical information
- Manufacturer feature 1: Tested and certified to meet ASTM E119 standards for 1-hour fire-rated wall assemblies, ensuring code compliance and safety. (United States; Source checked September 20, 2026)
- Manufacturer feature 2: High thermal performance combined with fire-resistant properties, ideal for projects requiring both insulation excellence and a 1-hour fire rating without compromise. (United States; Source checked September 20, 2026)
- Manufacturer feature 3: Lightweight InnovaCELL foam core enhances ease of handling and increase installation speed versus traditional fire-rated assemblies (United States; Source checked September 20, 2026)
- Manufacturer feature 4: Strength and rigidity of DM40-F+ enables longer panel lengths and design flexibility (United States; Source checked September 20, 2026)
- Manufacturer feature 5: Closed-cell foam technology mitigates vapor intrusion and reduces condensation risk compared to mineral wool. (United States; Source checked September 20, 2026)
- Manufacturer feature 6: Panel joinery is designed to permit installation of the panel vertically (United States; Source checked September 20, 2026)
- Manufacturer feature 7: Reduces the number of materials and steps needed, cutting down on labor time and installation costs (United States; Source checked September 20, 2026)
Current manufacturer scope
Use the current linked manufacturer data, specification, installation and load documents for the selected configuration. Verify panel thickness, facing, finish, attachment, span and complete tested assembly before construction.
Market: United States · Effective: Source checked September 20, 2026
Data sheets and technical documents
Current product files and retained historical revisions.
Current files
Archived files
No older reviewed revisions are archived for this product yet.
Identification and compatibility
Confirm the exact product name, profile, core or panel type, facing, thickness and label against the current manufacturer record. Similar profiles are not proof of identity.
Compatibility considerations
Coordinate the selected panel or component with the manufacturer-approved support, fasteners, clips, sealants, vapor control, flashings, trims and tested assembly.
Sources and citations
Technical reference note
Verify current suitability, availability, engineering performance, certification, warranty, and installation requirements with the manufacturer and the project design professional before specification or construction. Archived files do not represent current requirements.