Overview
Landmark PWR is a CertainTeed integrated solar roofing solution that combines an asphalt shingle roof with photovoltaic shingles. Each solar shingle is frameless and rated at 85 W. Individual shingles can be replaced. It works with most roof types, roofing materials and module-level electronics.
Electrical characteristics
- Maximum power at standard test conditions: 85 W. PV USA Test Conditions power: 77.8 W.
- Voltage at maximum power: 14.6 V. Current at maximum power: 5.82 A.
- Open circuit voltage: 17.4 V. Short circuit current: 6.14 A.
- Maximum system voltage: 600 V. Maximum series fuse rating: 15 A.
- Temperature coefficients: Pmax -0.303%/K, Voc -0.241%/K, Isc 0.037%/K.
- Nominal operating cell temperature: 20 degrees C. Active cell efficiency: 21.1%.
- Tested and passed temperature range: -40 to +85 degrees C.
Data sheets and technical documents
Current files
Archived files
No older reviewed revisions are archived for this product yet.
Mechanical characteristics
- Exposed area: 47.7 inches by 16.15 inches.
- Weight: 24 pounds.
- Cells: M10R half cut cells, 24 in series, with 2 bypass diodes per solar shingle.
- Design load: +2400/-1600 Pa.
- Wire: 12 AWG PV wire with Staubli MC4 connectors.
- Minimum roof pitch: 4/12.
Certifications and ratings
- UL 61730 and BIPV UL 7103.
- Fire: UL 790 Class A and C.
- Wind: ASTM D3161 Class F, 110 mph.
- Impact: FM4473 Class 3.
- California CEC Listed, pending.
- FBC HVHZ Approved, Vasd 150 mph and Vult 194 mph, pending.
- UL 3741, pending.
Warranty
The listed warranties are a 25 year limited power warranty, a 25 year limited workmanship warranty and a 10 year 110 mph limited wind warranty. The power output warranty figure printed is 98%.
Construction and compatibility
- Frameless laminate and glass construction
- Pairs with roofing materials up to 1 inch thick
- Works with a variety of module-level electronics
- Individual shingles can be removed and replaced
Use
Landmark PWR pairs with the Landmark family of residential shingle roofing products. The data sheet is code number 02-04-6418-US-EN, dated 07/26.