Super-Rib product profile

Super-Rib

Manufacturer
Metl-Span
Product
Super-Rib
Status
Current
Market
United States
Last verified
September 20, 2026

Super-Rib overview

Super-Rib is the strongest panel in the Metl-Span exposed fastener range, allowing longer spans and fewer supports.

Super-Rib is an exposed fastener, single-skin metal wall panel in the Metl-Span range, used as a metal wall panel in new construction and retrofit.

Profile and dimensions

Super-Rib is 24 inches wide with a 4 inch height and a 4 inch panel depth. The Super-Rib panel is made in lengths that run from 5′-0″ to 38′-0″. The Super-Rib exterior profile is a 4 inch rib height on center with staggered patterns.

Data sheets and technical documents

Current product files and retained historical revisions.

Current

Current files

Archive

Archived files

No older reviewed revisions are archived for this product yet.

Materials and finishes

The Super-Rib exterior face is G90 galvanized steel in 22, 20 and 18 gauge unembossed, or 22 and 20 gauge non-directional embossed.

The Super-Rib color offering is arranged in four tiers, Standard I, Standard II, a further tier I and tier II, and is supplied through a Metl-Span representative.

Joint and fastening

As a wall panel, Super-Rib side laps in the low cell. Used as a roof panel, it is inverted so that the side lap falls in the high cell.

Super-Rib has an overlapping side joint and is attached with an exposed fastening system.

Applications

Super-Rib can be used as an exterior or interior wall, with an insulated or non-insulated backup system. Installed in a rainscreen application, Super-Rib can form part of a system ranging from an uninsulated screen wall to BW Systems.

Features and options

Super-Rib ribs can run horizontally or vertically and can be curved to extreme degrees. Super-Rib has exceptional negative wind load properties.

Super-Rib is available embossed (non-directional) or unembossed, and the wall system installs with exposed fasteners from the outside face.

Design basis

The load span table for Super-Rib is based on Allowable Stress Design (ASD). For Super-Rib LRFD loads, section 2.4.1 of ASCE 7-10 applies. Super-Rib is specified under MasterFormat 2012 Section 07 42 13.19.