Overview

The CS-200 has 12 inch wide coverage and a 7/8 inch deep profiled panel with one asymmetrical rib. Concept Series wall panels come as CS-200, CS-260, CS-620 and CS-660. Horizontal or vertical rainscreen applications use the CS-200 as a single-skin wall panel.

Profile and dimensions

  • Coverage: 12 inches (305 mm).
  • Panel height: 0.875 inch (22 mm).
  • Profile: reveal-joint with a raised flat pan.
  • 200 Series panels are made in 12 inch widths.
  • Lengths: 5 feet (1524 mm) to 30 feet (9144 mm) as standard, with custom lengths on special order.

Data sheets and technical documents

Current product files and retained historical revisions.

Current

Current files

Archive

Archived files

No older reviewed revisions are archived for this product yet.

Joint and clips

The CS-200 joins neighboring panels with a common-lock joint and is fastened with concealed fasteners. Attachment uses the CSC-1 or CSC-3 clip, so there are two clip options. The galvanized steel clip is 0.06 inch (16 gage, 1.52 mm) thick.

Materials and finishes

The CS-200 is offered in embossed or unembossed surface. The steel is G90 (Class Z275) galvanized to ASTM A 653/A 653M, with thickness options of 0.030 inch (22 gage), 0.036 inch (20 gage) and 0.047 inch (18 gage). The 24 gage is not offered in this profile.

Installation

The CS-200 is installed horizontally or vertically in new construction and retrofit. It forms part of a wall system from an uninsulated screen wall to a system using BW Systems, an insulated composite backup panel system.

Comparison within the series

Within the Concept Series, the CS-200 has the single asymmetrical rib. The CS-260 has three ribs at the same 12 inch coverage, and the 16 inch CS-620 and CS-660 have two and four. Load span tables are based on Allowable Stress Design (ASD), and section 2.4.1 of ASCE 7-10 gives the ASD combinations for LRFD loads. The CS-200 is listed under 2012 MasterFormat Section 07 42 13.19.