Revision context
Document record
The file is a one-page PAC-CLAD spec sheet for the Tite-Loc Plus panel, marked 7/26 in its footer. It lists product features, materials, UL and ASTM classifications, tests limited to Tite-Loc Plus, approval wording, footnotes, specifications and panel conditions.
Specs are 12, 16 or 18 in. nominal on center at 2 in. high. The panel is offered in .032 and .040 aluminum and 24 and 22 gauge steel, with Galvalume Plus available. The feature list describes the panel as Herr-Voss corrective leveled. Smooth is standard, and striations, pencil ribs and striations with pencil ribs are optional and available by request.
The UL classifications are UL-580 Class 90 up to 18 in. on center, UL-1897 wind uplift, UL-790 Class A, UL-263 fire resistance and UL-2218 impact resistance. The Tite-Loc Plus tests record passed 24 gauge steel and .032 aluminum SSTD missile impact tests. The ASTM tests listed are E1592, E331/1646, E283/1680 and E2140. A footnote adds that 24 and 22 gauge Tite-Loc Plus panels are FM Approved in 12 in. and 16 in. widths over 16 gauge open purlins only. Florida and Miami-Dade approval numbers are listed by reference to the manufacturer’s website and factory.
Material changes / notes
Official file linked from the current catalogue. No local archive copy is retained. Publication date and revision have not been verified.