HR Series (HR5/HR5 with InnovaCELL™ Technology)

From the Total Cladding and Roofing Technical Library

Log in to edit
HR Series (HR5/HR5 with InnovaCELL™ Technology) product profile

HR Series (HR5/HR5 with InnovaCELL™ Technology)

Manufacturer
All Weather Insulated Panels
Product
HR Series (HR5/HR5 with InnovaCELL™ Technology)
Status
Current
Market
United States
Last verified
September 20, 2026

Overview

HR5 is the High Rib Roof Panel of the AWIP HR Series, also offered as HR5 with InnovaCELL Technology. It is an exposed-fastener insulated metal panel roof for retrofit and new construction. The roof is a single component that includes the exterior face, a weather barrier, insulation and a vapor barrier.

The interior surface is washable. The related HR5-W is the wall version, and the HR3 is the other roof panel in the series.

Profile and dimensions

  • Module width: 40 inches (1016 mm)
  • Thickness: 1.5, 2.5, 3, 4, 5 or 6 inches
  • Length: 8 feet (2.44 m) minimum to 50 feet (15.24 m) maximum
  • Exterior profile: trapezoid
  • Interior profile: embossed, lightly planked, Mesa rib
  • Exterior side lap: trapezoidal overlap
  • Interior side lap: shiplap
  • Minimum slope: 1:12

Data sheets and technical documents

Current product files and retained historical revisions.

Current

Current files

Archive

Archived files

No older reviewed revisions are archived for this product yet.

Materials and construction

The core is polyisocyanurate (PIR). The HR5 exterior skin is 26 gauge G90 galvanized or AZ50 Galvalume steel, with 24 and 22 gauge optional. The HR5 interior skin is 26 gauge G90 or AZ50, with 24 and 22 gauge optional, or 26 gauge 304 2B stainless steel for interior applications.

Panels are fastened with exposed through-fasteners. Published global warming potential for the HR5 is 5.6 to 10.4 lb CO2eq per square foot (27.3 to 50.9 kg CO2eq per square meter).

Thermal performance

The nominal R-value of the HR5 is 7.2 per inch at 75°F mean temperature and 8.2 per inch at 35°F mean temperature, by ASTM C518. The HR5 U-values come from ASTM C1363 tests at 2, 4 and 6 inch thicknesses and are not given for the 1.5 inch panel.

  • 1.5 inches: R-10.8 at 75°F mean and R-12.3 at 35°F mean
  • 2.5 inches: R-18.0 and U-0.087 at 75°F mean; R-20.5 and U-0.078 at 35°F mean
  • 3 inches: R-21.6 and U-0.073 at 75°F mean; R-24.6 and U-0.062 at 35°F mean
  • 4 inches: R-28.8 and U-0.040 at 75°F mean; R-32.8 and U-0.032 at 35°F mean
  • 5 inches: R-36.0 and U-0.031 at 75°F mean; R-41.0 and U-0.026 at 35°F mean
  • 6 inches: R-43.2 and U-0.022 at 75°F mean; R-49.2 and U-0.020 at 35°F mean

Tests and approvals

  • FM 4880: passed, Class 1 fire rating
  • FM 4471: passed as an FM Class 1 panel roof, with rated assemblies listed in RoofNav
  • ASTM E84: flame spread index 25 or less, smoke developed index 450 or less
  • ASTM E108: pass, installation into steel supports only
  • NFPA 286 and CAN/ULC S138: pass
  • CAN/ULC S126 fire spread under roof: pass
  • ASTM E1680 air infiltration: under 0.036 cfm per square foot at 20 PSF, tested at flat slope
  • ASTM E1646 water penetration: no leakage at 12 PSF, tested at flat slope
  • IAPMO ER-301
  • Texas Department of Insurance RC-683

Finishes and colors

The HR5 roof panel has a smooth, non-embossed exterior as its standard surface. Imperial White is its standard interior paint. Multilayer coil coats are offered beside the standard paints, and color chips are on request.

Roof construction

The HR5 is a composite panel. The exposed through-fasteners give an industrial look to the roof. The design is weathertight and suits both retrofit and new construction.