UltraPly TPO Coated Metal
- Manufacturer
- Elevate
- Product
- UltraPly TPO Coated Metal
- Status
- Current
- Market
- United States
- Latest revision
- Not confirmed
- Latest file date
- Not confirmed
- Last verified
- September 19, 2026
- Archived files
- 0
Product overview
UltraPly TPO Coated Metal is galvanized steel laminated with non-reinforced TPO for compatible flashing details. It is an accessory rather than field membrane. The technical sheet describes joint preparation and the heat-welded flashing connection.
Record scope
This page is the product-level record for UltraPly TPO Coated Metal. It separates this product from similar lines, variants and generations so that specifications and data sheets can be checked against the correct identity.
- Product family: Single-ply roofing
- Recorded applications: Low-slope commercial roofing
- Market: United States
- Manufacturer: Elevate
Key recorded details
These values summarize reviewed manufacturer information. Use the linked source for tolerances, options, exclusions and complete assembly requirements.
- Product family: Single-ply roofing
- Application: Low-slope commercial roofing
- Function: Flashing component for the UltraPly TPO system
- Construction: Non-reinforced TPO laminated to galvanized steel
- TPO coating thickness: 0.032 inch (0.81 mm), tolerance ±0.003 inch
- Sheet metal: 24 ga G-90 hot-dipped galvanized steel
- Sheet size: 4 × 10 feet
- Colors: White, gray, or tan
- Post-consumer recycled content: 22%
- Post-industrial recycled content: 6%
- Minimum robotic weld width: 1 1/2 inches
- Minimum hand weld width: 2 inches
Matched current documents
The following current files are connected directly to this product record. Older revisions remain in the archive when moderators retire them.
Design and specification coordination
Use these checks to connect the product record to a complete, project-specific assembly. The manufacturer documents and approved construction documents govern where they provide more specific requirements.
- Confirm membrane type, nominal thickness, reinforcement or fleece construction, color and roll dimensions.
- Coordinate the roof deck, vapor control, insulation, cover board and attachment method as one tested roof assembly.
- Verify adhesive or fastener compatibility, seam-welding requirements, perimeter enhancement and details at penetrations and edges.
- Check wind-uplift, fire and code listings for the complete assembly rather than relying on membrane properties alone.
- For recover work, document the existing roof, moisture survey, substrate preparation and separation-layer requirements.
Submittal and field verification
A useful product record should allow a reviewer to trace what was specified, approved, delivered and installed. Include the following items when this product is proposed or verified.
- Use the exact product name and manufacturer identifier on the submittal; do not substitute a similar family name.
- Attach the current product data sheet and the applicable installation, safety, approval and warranty documents.
- Record selected options such as size, thickness, profile, color, finish, reinforcement and attachment method.
- Identify the tested or approved assembly and list each adjoining component needed to reproduce it.
- At delivery, compare labels and revision dates with the approved record and archive superseded files instead of overwriting them.
Selection, installation and existing-roof checks
Confirm the exact product name, generation and configuration before using any value on this page. Check the roof substrate, slope, attachment or adhesive, reinforcement, edge and penetration details, accessories, tested assembly and local approval that apply to the project. For an existing roof, compare labels, package records, original submittals and physical dimensions; appearance alone is not enough to identify a product.
Applications and product scope
Recorded applications
- Low-slope commercial roofing
Record scope
- Product family: Single-ply roofing
- Recorded market: United States
- Product code: UltraPly TPO Coated Metal
Technical information
- Product family: Single-ply roofing (United States; Source checked September 19, 2026)
- Application: Low-slope commercial roofing (United States; Source checked September 19, 2026)
- Function: Flashing component for the UltraPly TPO system (United States; Source checked September 19, 2026)
- Construction: Non-reinforced TPO laminated to galvanized steel (United States; Source checked September 19, 2026)
- TPO coating thickness: 0.032 inch (0.81 mm), tolerance ±0.003 inch (United States; Source checked September 19, 2026)
- Sheet metal: 24 ga G-90 hot-dipped galvanized steel (United States; Source checked September 19, 2026)
- Sheet size: 4 × 10 feet (United States; Source checked September 19, 2026)
- Colors: White, gray, or tan (United States; Source checked September 19, 2026)
- Post-consumer recycled content: 22% (United States; Source checked September 19, 2026)
- Post-industrial recycled content: 6% (United States; Source checked September 19, 2026)
- Minimum robotic weld width: 1 1/2 inches (United States; Source checked September 19, 2026)
- Minimum hand weld width: 2 inches (United States; Source checked September 19, 2026)
Official technical information
Use the individual manufacturer document for the selected configuration. Check its revision and the complete assembly requirements before specification or installation.
Market: United States · Effective: Source checked September 19, 2026
Data sheets and technical documents
Current product files and retained historical revisions.
Current files
Archived files
No older reviewed revisions are archived for this product yet.
Identification and compatibility
Check packaging, product labels and original project submittals against the exact product name and document revision. The representative application photograph does not establish product identity.
Compatibility considerations
Verify the substrate, attachment, adjoining materials and accessories against the manufacturer’s complete assembly instructions. A shared brand or similar appearance does not establish interchangeability.
Sources and citations
Technical reference note
Verify current suitability, availability, engineering performance, certification, warranty, and installation requirements with the manufacturer and the project design professional before specification or construction. Archived files do not represent current requirements.