Permanent product record

K-Roc HF

ManufacturerKingspan
ProductK-Roc HF
StatusCurrent
MarketUSA
Latest known revisionNot confirmed
Latest documentDate not confirmed
Last verifiedAugust 30, 2026
Historical documents held0
Insulated metal wall panels enclosing a large industrial facility
Representative application image from the Total Roofing media library; it does not establish an exact K-Roc HF panel or fire-rated assembly. Confirm the complete tested assembly with current Kingspan documents.

Material and use

Popular uses and relevant services

  • Commercial walls
  • Fire-rated wall assemblies
  • Industrial walls
  • Washdown environments

Related Total Roofing services and guidance

Project suitability, engineering performance, fire compliance, and installation requirements must be confirmed for the specific building and current manufacturer specification.

What it is

Product overview

K-Roc HF is Kingspan’s current US insulated wall-panel range for applications requiring a mineral-fiber core and documented fire performance. The official catalogue lists embossed and non-embossed skins, several profiles and multiple panel thicknesses.

It may be evaluated for sensitive commercial or industrial wall conditions, including selected washdown environments. Fire-resistance duration depends on the complete tested assembly and installation requirements; a product-family name or thickness alone does not establish a project rating.

Current information

System particulars and performance

PropertyValueMarketEffective period
Insulation Core:Mineral FiberUSACurrent official catalogue record verified 2026-08-31
Profile:Exterior: Azteco™, Flat, Micro-Rib, Mini Micro-Rib, ShadowlineUSACurrent official catalogue record verified 2026-08-31
Interior: Shadowline USACurrent official catalogue record verified 2026-08-31
Embossing:Exterior: Stucco or non-embossed  (Azteco™ profile only available with Azteco™ embossing)USACurrent official catalogue record verified 2026-08-31
Interior: Stucco or non-embossed USACurrent official catalogue record verified 2026-08-31
Gauge:See profile specification section;  USACurrent official catalogue record verified 2026-08-31
Width:42";  USACurrent official catalogue record verified 2026-08-31
Thickness:4”, 6”, 8”;  USACurrent official catalogue record verified 2026-08-31
Length:8’ - 48’;  USACurrent official catalogue record verified 2026-08-31
Reveal Option:1/8”;  USACurrent official catalogue record verified 2026-08-31
Orientation:Vertical or horizontal;  USACurrent official catalogue record verified 2026-08-31
Post fabrication:N/A;  USACurrent official catalogue record verified 2026-08-31
R-value:3.8 per inch per ASTM C518 @ 75˚F mean temperatureUSACurrent official catalogue record verified 2026-08-31

Product Specification

Insulation Core: Mineral Fiber
Profile: Exterior: Azteco™, Flat, Micro-Rib, Mini Micro-Rib, Shadowline
Interior: Shadowline
Embossing: Exterior: Stucco or non-embossed (Azteco™ profile only available with Azteco™ embossing)
Interior: Stucco or non-embossed
Gauge: See profile specification section
Width: 42"
Thickness: 4”, 6”, 8”
Length: 8’ – 48’
Reveal Option: 1/8”
Orientation: Vertical or horizontal
Post fabrication: N/A
R-value: 3.8 per inch per ASTM C518 @ 75˚F mean temperature

Market: USA · Effective: Current official catalogue record verified 2026-08-31 · Confidence: Verified Primary Source

Verify this section with the manufacturer source

Testing and Approvals

Test Procedure Results
Fire FM 4880 Passed: Class 1 Fire Rating of Building Panels or Interior Finish Materials*
ASTM E119/ULC-S101 Application
Fire Rating Wall Ceiling
1 hour 4" 6"
1.5 hour 6" 6"
2 hour 6" 8"
3 hour 8" –
Consult Kingspan Technical Services for details on specific installation requirements.
ASTM E814 Listed up to 6” diameter steel pipe through penetration.
Consult Kingspan Technical Services for details.
ASTM E84 (mineral fiber core) Flame Spread: 0
Smoke Developed: 5
ULC-S114 Non-combustible
ULC-S115 Passed. Standard method of fire tests of firestop systems.
Structural ASTM E72 Vacuum chamber tested. Panel load/span and deflection tables are available.
Thermal Transmission ASTM C518 Thermal Performance at 75˚F mean temperature
Thickness R-Value
4" 15.2
6" 22.8
8" 30.4
Consult Kingspan Technical Services for details on specific installation requirements.
Air and Water ASTM E283 0.03 CFM/ft2 of panel area at 6.24 psf.
ASTM E331 No uncontrolled water penetration at 20 psf differential pressure.
Regional Approvals City of Los Angeles LCR-85599
FPA FL25618.1
*Thickness: 4”-8”, Width: 42”, Min. panel length: 8’, Min. gauge: Exterior 26 ga, Interior 26 ga. For FM compliance, systems must be installed in accordance with FM installation specifications as detailed on ApprovalGuide.com. Please contact technical.NA@kingspanpanels.com for detailed information or refer to ApprovalGuide.com.

Market: USA · Effective: Current official catalogue record verified 2026-08-31 · Confidence: Verified Primary Source

Verify this section with the manufacturer source

Individual files and document timeline

Current technical documents

Every file is listed separately and labelled by document type and format. Where publication rights are not yet confirmed, the individual download opens the official Kingspan file; the checksum-verified site archive remains private until republication is approved.

Chronology

Specification history

  1. August 30, 2026Library Record

    Technical Library first verified catalogue capture

    First verified Technical Library capture of the current US catalogue record. This is not evidence of product launch or manufacturer change.

    Technical Library record updated: August 30, 2026. This does not establish a manufacturer launch or change date.

Refurbishment research

Identifying older installations

No sufficiently reliable identification guidance is currently held. Product appearance alone may not establish the installed generation, market, or specification.

Product relationships

Replacement and related products

No evidence-supported direct replacement has been recorded. A similarly named product must not be assumed compatible.

Technical reference disclaimer

This library is a research and reference resource. Verify current suitability, availability, engineering performance, certification, warranty, and installation requirements with the manufacturer and the project design professional before specification or construction. Archived specifications do not represent current requirements.

Compiled by Total Roofing Technical Library · Last verified August 30, 2026