PAC-150 90° Seam
- Manufacturer
- PAC-CLAD | Petersen
- Product
- PAC-150 90° Seam
- Status
- Current
- Market
- United States
- Last verified
- September 7, 2026
Overview
The PAC-150 90° Seam is a mechanically seamed standing seam roof panel from PAC-CLAD, the Petersen brand. It belongs to the standing-seam roofing family and is used on commercial roofing in the United States. The panel is held by concealed clips and has a single-lock configuration.
The panel is seamed in the field to 90°. This 90° seam is one of two PAC-150 seam configurations, the other being the 180° seam, which is a double-lock configuration. It is part of the standing seam metal roofing systems used on commercial buildings, such as standing seam metal roof panels.
Profile and dimensions
PAC-150 panels have a seam height of 1-1/2 in. Nominal panel widths are 12 in, 16 in, 18 in and 20 in on center. The widths are nominal.
- Seam height: 1-1/2 in
- Nominal widths: 12 in, 16 in, 18 in or 20 in O.C.
- Listed minimum slope: 1:12
- Maximum panel length: 64 ft when factory or shop-formed
The 90° seam is formed by mechanical seaming in the field. Panels can be factory or shop-formed, or field-formed, and field-formed lengths are virtually unlimited.
Data sheets and technical documents
Current product files and retained historical revisions.
Current files
Archived files
No older reviewed revisions are archived for this product yet.
Pan variations
The panel is available in four pan variations. The smooth pan is the standard. Striated, pencil rib and flat rib pans are optional. Each variation keeps the 1-1/2 in height and the same four nominal widths.
Lengths and curving
Panels formed in the factory or shop run to a maximum of 64 ft, and the minimum length is approximately 4 ft. Field-formed lengths are virtually unlimited.
Panels can be curved in the field or at the factory, depending on radius and panel length. The minimum curve radius is 20 ft.
Materials
PAC-150 is formed from 24 gauge steel or .032 aluminum. Galvalume Plus is available as a steel option.
- 24 gauge steel
- .032 aluminum
- Galvalume Plus steel available
Seaming equipment
Seamers for the PAC-150 90° Seam are not available from Petersen. This differs from the 180° configuration, whose seamers are sold through a dedicated PAC-CLAD seamer site.
Classifications and approvals
The PAC-150 spec sheet carries three classifications under the heading UL Classification.
- UL-580
- UL-1897
- TAS-125
Florida Building Product Approvals for PAC-150 are handled through the Acworth, Georgia facility.
Warranty
A 35-year non-prorated finish warranty applies to the product. A weathertightness warranty is also available.
Finish and production
Colors are Kynar-based 70% PVDF coatings. The PAC-CLAD color guide groups colors into standard, metallic and cool ranges.
The panel is produced only at the Georgia, Maryland and Arizona facilities of Petersen. The facilities are in Acworth, Georgia, in Baltimore, Maryland, and in Phoenix, Arizona.
Seaming
The 90° seam is closed with a mechanical seamer in the field.
Mechanical seamers are required. On slopes greater than 6:12, seamer slippage can scratch the finish, and the scratches may void the warranty. D.I. Roof Seamers is the only supplier of seaming equipment approved by Petersen, and it also supplies hand crimpers and other tools.
Test data and listings
- FBC Approval 16942 R1 (2014 Code)
- UL 90 Construction No. 603 (.032 aluminum)
- UL 90 Construction No. 588 (24 gauge steel)
- Test listings for .032 aluminum and 24 gauge steel over plywood deck
- Load tables n0374.03-450-18-r0 (.032 aluminum) and n0374.04-450-18-r0 (24 gauge)
- Florida HVHZ roofing approval
- Miami-Dade Notices of Acceptance
- UL Fire Directory listing
- Design pressure chart: PAC-150 MDP chart
Details and accessories
Detail drawings are published in PDF and CAD formats for metal deck (ISO) and wood substrates. Subjects include curb, eave, expansion joint, gable, gutter, headwall, hip and ridge, panel end, peak, pipe penetration, rakewall, slope change, membrane transition, valley, valleywall and Z-closure details. Vented ridge details with Corr-a-Vent are for wood substrates only.
A 3-part specification and a DOCX specification for the 24 gauge by 12 market version exist.
Installing this in San Antonio or Austin?
We install R-panel roofs and wall cladding on commercial and industrial buildings from our Bulverde office.
Contribution history
Published changes remain in this permanent record. Corrections create a new entry instead of deleting earlier history.
- September 7, 2026 at 2:41 pmLibrary Record
Technical Library first verified catalogue capture
First verified capture of the current official product page. Website record update only; not evidence of product launch or manufacturer change.
By TCR editorial team · Verified Primary Source