IW Series: IW-40A
- Manufacturer
- Metl-Span
- Product
- IW Series: IW-40A
- Status
- Current
- Market
- United States
- Last verified
- September 20, 2026
Overview
The IW-40A is a 12 inch wide concealed fastener panel with an 11 inch flat and a 1 inch recess. The IW-40A is the fourth profile of the IW Series, which also includes the IW-10A, IW-13A and IW-20A. The IW-40A is a concealed fastener metal wall panel that is used as horizontal or vertical rainscreen cladding on commercial and industrial buildings.
Profile and dimensions
- Coverage: 12 inches (305 mm).
- Panel height: 1.50 inches (38 mm).
- Profile: one inch (25 mm) reveal-joint with a raised flat pan.
- Flat: 11 inches; recess: 1 inch.
- Panel length runs from 5 feet to 25 feet; other lengths are special orders.
Data sheets and technical documents
Current product files and retained historical revisions.
Current files
Archived files
No older reviewed revisions are archived for this product yet.
Joint and fastening
The common lock joint of the series is part of the IW-40A. It minimizes moisture intrusion, hides the fasteners and lets IW-40A panels be combined with other IW profiles. A factory-installed sealant in the side joint of the IW-40A helps minimize water intrusion.
Face sheet options
The IW-40A uses the series face sheet: coil-coated steel to ASTM A 755/A 755M on G90 zinc-coated base metal. Nominal uncoated thickness options run from 0.030 inch (22 gage) to 0.047 inch (18 gage). Sheet is non-directional embossed or unembossed.
Test performance
Installed over insulated composite backup panels, the IW Series assembly is rated at a maximum 0.06 cfm/sq. ft. (0.3 L/s per sq. m) air infiltration per ASTM E 283 at 1.57 lb/sq. ft. (75 Pa), with no uncontrolled water penetration per ASTM E 331 at 6.24 lb/sq. ft. (299 Pa), on a test panel of at least 10 by 10 feet that includes side joints. Wall panel assemblies are limited to L/180 deflection under scheduled wind pressure. The load span table for the IW-40A is published as a separate file.
Load span and specification
The IW-40A data are given under 2012 MasterFormat Section 07 42 13.19, with load span tables based on Allowable Stress Design (ASD). ASCE 7-10 (LRFD) loads are converted to ASD combinations using section 2.4.1 of ASCE 7-10. Where foam plastic insulation is part of the wall system, the system is tested by the foam plastic supplier in accordance with NFPA-285.