TCR Twin-Skin Insulated Metal Roof

From the Total Cladding and Roofing Technical Library

Log in to edit
Exploded concept illustration of outer R-panel, spacer rails and legs, fiberglass blanket and sealed R-panel liner.

TCR Twin-Skin Insulated Metal Roof

Manufacturer
Total Cladding and Roofing
Product
TCR-TSR-001 / Concept 0.1
Status
Current
Market
United States
Latest revision
0.1
Latest file date
September 7, 2026
Last verified
September 7, 2026

Product overview

A proposed site-assembled roof with an R-panel liner, variable-depth spacers, loose-laid fiberglass and an outer R-panel weather sheet. Concept revision 0.1 for project discussion; not a tested/listed assembly.

Record scope

This page is the product-level record for TCR Twin-Skin Insulated Metal Roof. It separates this product from similar lines, variants and generations so that specifications and data sheets can be checked against the correct identity.

  • Product family: Site-assembled insulated metal roofing
  • Recorded applications: Commercial roofs, Warehouses and industrial buildings
  • Market: United States
  • Manufacturer: Total Cladding and Roofing

Key recorded details

These values summarize reviewed manufacturer information. Use the linked source for tolerances, options, exclusions and complete assembly requirements.

  • System status: Design-development concept; not a tested/listed proprietary assembly
  • Build-up: R-panel liner; spacer rails/legs; unfaced fiberglass; roofing-rated outer R-panel
  • Insulation zone: 5–16 inches illustrated; exact spacer geometry and availability require design
  • Thermal basis: Knauf Performance+ cavity insulation; nominal R-16/19/25 at 5/6/8 inches
  • Whole-roof U-factor: Not established. Calculate actual spacer, fastener and profile thermal bridges.
  • Side-lap liner tape: 50 x 1 mm ≈ 2 in x 40 mil; exact Q131 size subject to supplier confirmation
  • End-lap liner seal: 5 x 6 mm ≈ 3/16 x 1/4 in; bead shape and compression require review
  • Fire performance: Insulation ASTM E136 data; no TCR roof assembly fire rating assigned
  • 5 in insulation / 127.0 mm: Nominal R-16; insulation-only U 0.355 W/m²·K (0.0625 Btu/h·ft²·°F) Insulation only
  • 6 in insulation / 152.4 mm: Nominal R-19; insulation-only U 0.299 W/m²·K (0.0526 Btu/h·ft²·°F) Insulation only
  • 8 in insulation / 203.2 mm: Nominal R-25; insulation-only U 0.227 W/m²·K (0.04 Btu/h·ft²·°F) Insulation only
  • 10 in insulation / 254.0 mm: Nominal R-32; insulation-only U 0.177 W/m²·K (0.0312 Btu/h·ft²·°F) Insulation only
  • 12 in insulation / 304.8 mm: Nominal R-38; insulation-only U 0.149 W/m²·K (0.0263 Btu/h·ft²·°F) Insulation only
  • 14 in insulation / 355.6 mm: Nominal R-44; insulation-only U 0.129 W/m²·K (0.0227 Btu/h·ft²·°F) Insulation only
  • 16 in insulation / 406.4 mm: Nominal R-50; insulation-only U 0.114 W/m²·K (0.02 Btu/h·ft²·°F) Insulation only

Matched current documents

The following current files are connected directly to this product record. Older revisions remain in the archive when moderators retire them.

Design and specification coordination

Use these checks to connect the product record to a complete, project-specific assembly. The manufacturer documents and approved construction documents govern where they provide more specific requirements.

  • Confirm panel profile, coverage width, seam or rib geometry, metal type, gauge or thickness and finish.
  • Coordinate minimum slope, substrate, underlayment, clip or fastener selection and allowance for thermal movement.
  • Verify perimeter, ridge, valley, transition, penetration and closure details with the selected panel configuration.
  • Check tested wind-uplift, fire, water and air assemblies against deck type, span and attachment spacing.
  • Record manufacturing length limits, field-seaming requirements, finish availability and protection during storage and handling.

Submittal and field verification

A useful product record should allow a reviewer to trace what was specified, approved, delivered and installed. Include the following items when this product is proposed or verified.

  • Use the exact product name and manufacturer identifier on the submittal; do not substitute a similar family name.
  • Attach the current product data sheet and the applicable installation, safety, approval and warranty documents.
  • Record selected options such as size, thickness, profile, color, finish, reinforcement and attachment method.
  • Identify the tested or approved assembly and list each adjoining component needed to reproduce it.
  • At delivery, compare labels and revision dates with the approved record and archive superseded files instead of overwriting them.

Selection, installation and existing-roof checks

Confirm the exact product name, generation and configuration before using any value on this page. Check the roof substrate, slope, attachment or adhesive, reinforcement, edge and penetration details, accessories, tested assembly and local approval that apply to the project. For an existing roof, compare labels, package records, original submittals and physical dimensions; appearance alone is not enough to identify a product.

Applications and product scope

Technical information

  • System status: Design-development concept; not a tested/listed proprietary assembly
  • Build-up: R-panel liner; spacer rails/legs; unfaced fiberglass; roofing-rated outer R-panel
  • Insulation zone: 5–16 inches illustrated; exact spacer geometry and availability require design
  • Thermal basis: Knauf Performance+ cavity insulation; nominal R-16/19/25 at 5/6/8 inches
  • Whole-roof U-factor: Not established. Calculate actual spacer, fastener and profile thermal bridges.
  • Side-lap liner tape: 50 x 1 mm ≈ 2 in x 40 mil; exact Q131 size subject to supplier confirmation
  • End-lap liner seal: 5 x 6 mm ≈ 3/16 x 1/4 in; bead shape and compression require review
  • Fire performance: Insulation ASTM E136 data; no TCR roof assembly fire rating assigned
  • 5 in insulation / 127.0 mm: Nominal R-16; insulation-only U 0.355 W/m²·K (0.0625 Btu/h·ft²·°F) Insulation only
  • 6 in insulation / 152.4 mm: Nominal R-19; insulation-only U 0.299 W/m²·K (0.0526 Btu/h·ft²·°F) Insulation only
  • 8 in insulation / 203.2 mm: Nominal R-25; insulation-only U 0.227 W/m²·K (0.04 Btu/h·ft²·°F) Insulation only
  • 10 in insulation / 254.0 mm: Nominal R-32; insulation-only U 0.177 W/m²·K (0.0312 Btu/h·ft²·°F) Insulation only
  • 12 in insulation / 304.8 mm: Nominal R-38; insulation-only U 0.149 W/m²·K (0.0263 Btu/h·ft²·°F) Insulation only
  • 14 in insulation / 355.6 mm: Nominal R-44; insulation-only U 0.129 W/m²·K (0.0227 Btu/h·ft²·°F) Insulation only
  • 16 in insulation / 406.4 mm: Nominal R-50; insulation-only U 0.114 W/m²·K (0.02 Btu/h·ft²·°F) Insulation only

System concept

Four coordinated layers: a sealed R-panel liner, engineered spacer rails and legs, loose-laid unfaced fiberglass blankets and a roofing-rated outer R-panel sheet. Components are selected for each project; the illustration is conceptual and not to scale.

Thermal calculations

The table below uses Knauf published single-layer ratings and calculated multilayer sums. 10/12/14/16-inch options use 5+5 / 6+6 / 6+8 / 8+8-inch layers. RSI = US R / 5.6783; U(SI) = 1/RSI. Surface films, air spaces and thermal bridges are excluded. No completed-roof U-factor or energy-code compliance is assigned.

Liner seals and US candidates

Review Alpha Q131 for approximately 2-inch x 40-mil side-lap tape. SFS offers metal-panel butyl tape, including a 3/16-inch bead that is not an exact rectangular 5 x 6 mm replacement. Use profile-matched nonvented foam closures with compatible butyl mastic; SikaLastomer-511 is a candidate requiring written foam/coating and field-detail acceptance. Seal transitions, fixing penetrations and all laps, and verify leakage against project criteria.

Texas project design

Coordinate wind uplift, structural capacity, drainage, roof slope, interior conditions and seasonal moisture behavior. Leg height must preserve full insulation thickness around profile geometry. A vapor-control strategy developed for a different climate zone must not simply be copied into a hot-humid air-conditioned building.

Fire performance

The selected unfaced fiberglass has documented ASTM E136 noncombustibility and ASTM E84/UL 723 25/50 surface-burning data. These material properties do not establish a roof-covering or hourly assembly fire rating. Obtain applicable evidence for the complete construction.

Data sheets and technical documents

Current product files and retained historical revisions.

Current

Current files

Archive

Archived files

No older reviewed revisions are archived for this product yet.

Identification and compatibility

This is concept revision 0.1, not an identification guide for an existing proprietary roof. Record actual profiles, supports, materials and original project documents before considering replacement work.

Compatibility considerations

Do not substitute panels, spacer legs, insulation, tapes or closures solely on appearance or nominal size. Confirm structural, thermal, moisture, fire and material compatibility for the project.

Sources and citations