PAC-Shield Roof and Wall Insulation

From the Total Cladding and Roofing Technical Library

Log in to edit
PAC-CLAD PAC-Shield polyiso insulation board illustration

PAC-Shield Roof and Wall Insulation

Manufacturer
PAC-CLAD | Petersen
Product
PAC-Shield Roof & Wall Insulation
Status
Current
Market
United States
Last verified
September 7, 2026

Overview

PAC-Shield is the polyisocyanurate (polyiso) insulation line from Petersen under the PAC-CLAD name, made for roof and wall assemblies. The roof boards use a closed-cell polyisocyanurate foam core produced on-line and bonded to fiber-reinforced facers on both sides. They are made with NexGen Chemistry and contain no CFCs, HFCs or HCFCs, with zero ozone depletion potential.

Roof insulation boards

The roof insulation range has four profiles:

  • PAC-Shield. The standard board. R-values range from R 5.7 to R 26.8.
  • PAC-Shield CV. A ventilated insulation panel for metal, slate and tile roofs.
  • PAC-Shield Coated Glass. A roof insulation profile with coated glass facers.
  • PAC-Shield Nail Base. A roof insulation profile with a nailable top facer.

Data sheets and technical documents

Current product files and retained historical revisions.

Current

Current files

No current reviewed file has been matched to this product yet.

Archive

Archived files

No older reviewed revisions are archived for this product yet.

Standard board data

  • Thickness: 1 inch to 4.5 inches (25 mm to 114 mm).
  • Board sizes: 4 ft x 4 ft (1220 mm x 1220 mm) and 4 ft x 8 ft (1220 mm x 2440 mm).
  • Compressive strength: 20 psi or 25 psi.
  • Grades meet ASTM C1289 Type II, Class 1: Grade 2 (20 psi) or Grade 3 (25 psi).
  • Special cuts: straight cut, bevel cut and flute fill.

The board is approved for direct application to steel decks and for use under built-up, modified bitumen and single-ply roof coverings. A multilayer installation with staggered joints is the recommended arrangement for thermal performance.

The roof board R-values run from R 5.7 to R 26.8, and the thickness range is 1 to 4.5 inches. Published downloads for the roof line cover a facer guide, fastening pattern, packaging and weights, storage and handling, and a safety data sheet.

Applications

The standard board is used under standing seam metal roof systems, single-ply systems (ballasted, mechanically attached and fully adhered), modified bitumen systems and built-up roofing in asphalt and coal tar. It is intended for constructions that require FM Class 1 and UL Class A ratings. See flat roofing systems and insulation for the low-slope assemblies these boards are used in.

Wall insulation boards

The wall range has seven profiles, all used as continuous insulation:

  • PAC-Shield CI Ply
  • PAC-Shield CI Ply (Class A)
  • PAC-Shield CI Nail Base
  • PAC-Shield CI Foil
  • PAC-Shield CI Foil (Class A)
  • PAC-Shield CI Coated Glass
  • PAC-Shield CI Coated Glass (Class A)

Environmental data

The line contains no HFCs, CFCs or HCFCs and is made using recycled materials. It has virtually no global warming potential. It can contribute to LEED credits for Optimize Energy Performance, Building Life-Cycle Impact Reduction, Environmental Product Declaration, Material Reuse, Recycled Content, Construction and Demolition Waste Management and Thermal Comfort.

Contribution history

Published changes remain in this permanent record. Corrections create a new entry instead of deleting earlier history.

  1. September 7, 2026 at 2:41 pmLibrary Record

    Technical Library first verified catalogue capture

    First verified capture of the current official product page. Website record update only; not evidence of product launch or manufacturer change.

    By TCR editorial team · Verified Primary Source