DEKFAST #14 Roofing Screws
- Manufacturer
- Triangle Fastener Corporation
- Product
- DEKFAST #14 Roofing Screws
- Status
- Current
- Market
- United States
- Last verified
- October 15, 2026
DEKFAST #14 Roofing Screws
DEKFAST #14 roofing screws are low slope roofing screws with a #14 drill point. They are used for a variety of connections and attach rigid insulation to steel or wood deck in low-slope roof assemblies.
The screw has a truss head with a #3 cross recess drive. Thread dimensions are .242 in major diameter and .151 in minor diameter. The carbon steel screw is epoxy coated and attaches to wood, concrete, or steel up to 16 ga (.060 in | 1.52 mm). The 410 stainless steel screw is passivated and attaches to wood or steel up to 18 ga (.048 in | 1.22 mm). Its self-drilling point penetrates steel quickly and can also be used in treated wood.
Sizes
- #14 carbon steel: 1-1/4, 2 and 3 in long, fully threaded; 4, 5, 6, 7, 8, 9, 10, 11 and 12 in long with 3-7/8 in thread length
- #14 410 stainless steel: 1-1/2, 2 and 3 in long, fully threaded; 4, 5, 6, 7, 8, 9, 10, 11 and 12 in long with 3-7/8 in thread length
- Packaging: 1000 pieces per box for 1-1/4 to 6 in lengths; 500 pieces per box for 7 to 12 in lengths
Data sheets and technical documents
Current files
Archived files
No older reviewed revisions are archived for this product yet.
Head, drive and coating
- Truss head: .437 in head diameter, .116 in head height
- Drive: #3 cross recess
- Carbon steel: epoxy coated
- 410 stainless steel: passivated
- Corrosion protection: meets or exceeds FM4470 corrosion standards per the Kesternich DIN 50018 SFW 2.0 test of 15 cycles
- Ultimate load: tensile 3,300 lb min.; shear 2,100 lb min.; torsional 110 lb-in min.
- Pullout in wood: 590 lb in 3/4 in fire rated plywood; 605 lb in 2x dimensional lumber with 1 in embedment
- Pullout in 4000 PSI concrete, carbon steel only: 850 lb with 1 in embedment; 3/16 in carbide tip drill bit, hole at least 1/2 in deeper than the embedment
- Installation: 2,000 RPM max screw gun with torque control; metal deck penetration of at least 3/4 in; concrete and wood embedment of at least 1 in or at least 3/4 in penetration beyond the wood decking
Approvals and listings
- FM Approved